Kit | KIT-XZ25-ZKE-H | KIT-XZ35-ZKE-H | KIT-XZ42-ZKE-H |
Cooling capacity (Nominal) | kW | 2,50 | 3,50 | 4,20 |
Cooling capacity (Min) | kW | 0,85 | 0,85 | 0,85 |
Cooling capacity (Max) | kW | 3,50 | 4,20 | 5,00 |
EER (Nominal) (1) | W/W | 4,90 | 4,27 | 3,39 |
EER (Min) (1) | W/W | 5,00 | 4,25 | 3,62 |
EER (Max) (1) | W/W | 3,89 | 3,62 | 3,18 |
SEER (2) | 7,50 A++ | 8,50 A+++ | 7,90 A++ |
Pdesign (cooling) | kW | 2,10 | 2,50 | 5,00 |
Input power cooling (Nominal) | kW | 0,45 | 0,52 | 1,41 |
Input power cooling (Min) | kW | 0,24 | 0,24 | 0,28 |
Input power cooling (Max) | kW | 0,56 | 0,79 | 1,95 |
Annual energy consumption cooling (3) | kWh/a | 98,00 | 103,00 | 222,00 |
Heating capacity (Nominal) | kW | 2,80 | 3,40 | 5,80 |
Heating capacity (Min) | kW | 0,70 | 0,80 | 0,98 |
Heating capacity (Max) | kW | 4,00 | 5,00 | 8,00 |
Heating capacity at -7°C | kW | 2,38 | 2,95 | 4,80 |
COP (Nominal) (1) | W/W | 4,52 | 4,79 | 4,03 |
COP (Min) (1) | W/W | 3,89 | 4,44 | 2,88 |
COP (Max) (1) | W/W | 4,04 | 3,97 | 3,16 |
SCOP (2) | 4,70 A++ | 5,10 A+++ | 4,70 A++ |
Pdesign at -10°C | kW | 2,10 | 2,70 | 4,20 |
Input power heating (Nominal) | kW | 0,62 | 0,71 | 1,44 |
Input power heating (Min) | kW | 0,18 | 0,18 | 0,34 |
Input power heating (Max) | kW | 0,99 | 1,26 | 2,53 |
Annual energy consumption heating (3) | kWh/a | 626 | 741 | 1251 |
Indoor unit | CS-XZ25ZKEW-H | CS-XZ35ZKEW-H | CS-XZ42ZKEW-H |
Indoor power source | V | 230 | 230 | 230 |
Indoor recommended fuse | A | 16 | 16 | 16 |
Indoor connection indoor / outdoor | mm² | 4 x 1,5 | 4 x 1,5 | 4 x 2,5 |
Indoor air flow (Cool) | m³/min | 9,9 | 10,2 | 19,1 |
Indoor air flow (Heat) | m³/min | 10,7 | 11,2 | 20,5 |
Moisture removal volume | L/h | 1,3 | 1,5 | 2,8 |
Indoor sound pressure (Cool -Hi) (4) | dB(A) | 37 | 39 | 44 |
Indoor sound pressure (Cool -Lo) (4) | dB(A) | 24 | 25 | 37 |
Indoor sound pressure (Cool -Q-Lo) (4) | dB(A) | 19 | 19 | 30 |
Indoor sound pressure (Heat -Hi) (4) | dB(A) | 38 | 41 | 44 |
Indoor sound pressure (Heat -Lo) (4) | dB(A) | 25 | 27 | 37 |
Indoor sound pressure (Heat -Q-Lo) (4) | dB(A) | 19 | 19 | 30 |
Indoor dimension (Height) | mm | 295 | 295 | 302 |
Indoor dimension (Width) | mm | 919 | 919 | 1120 |
Indoor dimension (Depth) | mm | 194 | 194 | 236 |
Indoor net weight | kg | 9 | 10 | 12 |
nanoe X Generator | Mark 1 | Mark 1 | Mark 1 |
Outdoor unit | CU-Z25ZKE | CU-Z35ZKE | CU-Z42ZKE |
Outdoor air flow (Cool) | m³/min | 26,9 | 28,7 | 39,8 |
Outdoor air flow (Heat) | m³/min | 24,1 | 27,2 | 36,9 |
Outdoor sound pressure (Cool -Hi) (4) | dB(A) | 45 | 46 | 47 |
Outdoor sound pressure (Heat -Hi) (4) | dB(A) | 46 | 47 | 47 |
Outdoor dimension (Height) (5) | mm | 542 | 542 | 695 |
Outdoor dimension (Width) (5) | mm | 780 | 780 | 875 |
Outdoor dimension (Depth) (5) | mm | 289 | 289 | 320 |
Outdoor net weight | kg | 27 | 31 | 42 |
Pipe diameter (Liquid) | Inch (mm) | 1/4 (6,35) | 1/4 (6,35) | 1/4 (6,35) |
Pipe diameter (Gas) | Inch (mm) | 3/8 (9,52) | 3/8 (9,52) | 1/2 (12,70) |
Pipe length range | m | 3 ~ 15 | 3 ~ 15 | 3 ~ 30 |
Elevation difference (in/out) (6) | m | 15 | 15 | 15 |
Pipe length for additional gas | m | 7,5 | 7,5 | 7,5 |
Additional gas amount | g/m | 10 | 10 | 15 |
Refrigerant (R32) / CO2 Eq. | kg / T | 0,70 / 0,473 | 0,85 / 0,574 | 1,15 / 0,776 |
Operating range (Cool – Min) | °C | -10 | -10 | -10 |
Operating range (Cool – Max) | °C | +43 | +43 | +43 |
Operating range (Heat – Min) | °C | -15 | -15 | -15 |
Operating range (Heat – Max) | °C | +24 | +24 | +24 |